ZAHNER-Elektrik GmbH & Co.KG
Thueringer Strasse 12
96317 Kronach
Germany
support@zahner.de
ZAHNER® Solutions
Cell Kits

KMZ3 / KMZ5

KMZ35 The corrosion measuring cells KMZ3 and KMZ5 are triple electrode cells for standard electrochemical measurements. Their application fields mainly are:

  • Corrosion test
  • Electrochemcial research
  • Metallography
  • Quality Assurance
  • Biotechnology
  • Microelectronics

The KMZ5 is a water-jacketed cell with a cell container suitable for connection to constant temperature circulators. The KMZ3 is the non-water-jacketed version. The measuring cells have different cell tops with standard taper joints (NS) for the insertion of the working and the counter electrodes, as well as the intermediate vessel with reference electrode and liquid junction tube including a "Haber Luggin capilary". All electrodes have glass bodies with standard tapers. The cells feature a user-friendly handling and a wide range of applications.

KMZ3 and KMZ5 come with: specimen holder (WE), counter electrode, reference electrode (Calomel), liquid junction tube, intermediate vessel, gas in- and outlet.

The following options are available: reference electrode (Ag/AgCl), thermometer, glass stirrer.


Specifications
KMZ3 KMZ5
Cell container glass, max. 130 mm in diameter glass, max. 130 mm in diameter, jacketed with tube connection
Capacity max. 500 ml max. 500 ml
Cell top about 120 mm in diameter about 120 mm in diameter
Operating temperature max. 50°C max. 110°C
Specimen holder PP, NS-29 PP, NS-29
Counter electrode NS-24, platinum sheet 4 cm2 NS-24, platinum sheet 4 cm2
Gas in- and outlet glass pipe, NS-14.5 glass pipe, NS-14.5
Reference electrode KE 10 / NSK 7 (Calomel, 60°C) KE 10 / NSK 7 (Calomel, 60°C)
Liquid junction tube 2 parts, NS-19 / NS-17, w. Haber Luggin capilary sleeve junctions 2 parts, NS-19 / NS-17, w. Haber Luggin capilary sleeve junctions
Intermediate vessel glass, NS-29 / 2 x NS-7 glass, NS-29 / 2 x NS-7
Materials PVC, PP, glass PP, glass

AMZ60
AMZ60

The area measuring cell AMZ60 is a triple electrode cell for electrochemical testing of coated samples. The application fields are:

  • Tests on Coatings, Laminates and Layers
  • Electrochemcial research
  • Quality Assurance
  • Biotechnology
  • Microelectronics







Specifications
AMZ60
Cell container plexiglass tube
Measuring area 6 cm2
Minimum width of sample 5 cm
Maximum width of sample 10 cm
Counter electrode stainless steel rod
Reference electrode Ag/AgCl
Working electrode specimen
Cell Kits

Product Selection

Corrosion Measuring Cells: KMZ3 / KMZ5

Area Measuring Cell: AMZ60

Manuals

KMZ3 / KMZ5
PDF-Document m_kmz35.pdf (PDF)
AMZ60
PDF-Document m_amz60.pdf (PDF)