High-end Data Acquisition Systems
ZAHNER-Elektrik GmbH & Co.KG
Thueringer Strasse 12
96317 Kronach
Germany
support@zahner.de
Stay on Top!
With the Best Solutions
in Electrochemical Applications
With the Best Solutions
in Electrochemical Applications
ZAHNER® Solutions
CIMPS
Controlled Intensity Modulated Photo Spectroscopy
The Zahner CIMPS system based on LED arrays brings an additional advantage compared to the IMPS described in the literature: a control loop regulates light intensity and modulation and keeps it absolutely stable. The automatic comparison between set value and sensed intensity eliminates the influence of non-linearity, ageing and temperature drift. Furthermore, it allows the direct calibration of the light source in units of intensity (W/m2).
The CIMPS package consists of several components, working together in a plug & play application, including software and an overall calibration of the system. An ElectroChemical Workstation ECW IM6 or ZENNIUM acts as a Frequency Response Analyser and as a support unit (Potentiostat / Galvanostat) for the cell under test. The IM-series workstations are renowned for their high precision, ease of use and comprehensive software. A slave potentiostat, driven by the IM6/IM6e system, controls amplitude and modulation of the light source over a wide range of frequencies.
0
An optical bench carries the housing of the light source with the integrated photo-amplifier and the slide with the photo-electrochemical cell (PECC-1 and PECC-2). A photodiode sensor is mounted near the site of the cells light inlet, adjustable in height and angle. Depending on the application, you can chose from different types of light sources (see table).
The Zahner CIMPS system based on LED arrays brings an additional advantage compared to the IMPS described in the literature: a control loop regulates light intensity and modulation and keeps it absolutely stable. The automatic comparison between set value and sensed intensity eliminates the influence of non-linearity, ageing and temperature drift. Furthermore, it allows the direct calibration of the light source in units of intensity (W/m2).
The CIMPS package consists of several components, working together in a plug & play application, including software and an overall calibration of the system. An ElectroChemical Workstation ECW IM6 or ZENNIUM acts as a Frequency Response Analyser and as a support unit (Potentiostat / Galvanostat) for the cell under test. The IM-series workstations are renowned for their high precision, ease of use and comprehensive software. A slave potentiostat, driven by the IM6/IM6e system, controls amplitude and modulation of the light source over a wide range of frequencies.
0
An optical bench carries the housing of the light source with the integrated photo-amplifier and the slide with the photo-electrochemical cell (PECC-1 and PECC-2). A photodiode sensor is mounted near the site of the cells light inlet, adjustable in height and angle. Depending on the application, you can chose from different types of light sources (see table).
CIMPS Software OptionThe ZAHNER CIMPS measurement system has been designed to match the special demands of dynamic photo-electric investigations. Besides traditional electrochemical investigations supported by the Thales software package a variety of special photo electric measurements can be done easily with the CIMPS option:
- SC fill-factor efficency
- Maximum power
- Intensity modulated photocurrent spectroscopy (IMPS)
- Controlled IMPS (CIMPS)
- Intensity modulated photovoltage spectroscopy (IMVS)
- Controlled IMVS (CIMVS)
- Charge extraction after N. W. Duffy, L. M. Peter et. al.
- Light transient measurements
- Time domain measurements
- Cross transfer function measurements (CTF)
(e.g. membrane penetration transfer function) - Intensity-DC transfer functions
Available CIMPS-Systems
| CIMPS-Systems | |
| CIMPS-1 | Complete CIMPS system with
|
| CIMPS-2 | Complete CIMPS system with
|
| CIMPS-3 | Complete CIMPS system with
|
| CIMPS-4 | Complete CIMPS system with
|
| CIMPS-abs | Absorption Option CIMPS system with
|
| CIMPS-emit | Emission Option CIMPS system with
|
| CIMPS-pcs | Photo Current Spectra Option CIMPS system with
|
Main Differences between PP211 and XPot as Lightsource Supply
| PP211 | XPot | |
| Frequency range | 10 μHz ... 100 kHz | 10 μHz ... 250 kHz |
| Supply output range for LED light source |
±10 A, ±20 V | ±500mA, ±10 V |
Optional Hardware
| SEL033 | NIST-traceable calibration sensor For automatic calibration procedure at the customer's lab |
| SIMPECC | Demo-board Electronic board for simulation of a PECC cell loaded with a sample |
| PECC-1 | PECC-2 | |
| Physical dimensions (W x D x H) | 60 x 25 x 80 mm | 60 x 25 x 80 mm |
| Optical window diameter | 20 mm | 18 mm |
| Optical window material | BK7 or Quartz | BK7 or Quartz |
| Working electrode diameter | max. 20 mm | max. 18 mm |
| Solid material | Teflon (PTFE) | Kel-F (PCTFE) |
| Reference electrode | Ag/AgCl | Ag/AgCl |
| Counter electrode | Pt coil | Pt coil |
| Gas inlet/outlet | No | Yes |
Available Light Sources for CIMPS
| Color | Dominant Wavelength (nm), typical | Spectral Halfwidth (nm), typical | Maximum Flux (lm) or Output Power (mW), typical | Viewing Angle 2θ ½ (degree), typical | Part Code Number |
| White | (3300K) | - | 14 lm | 20 | WLL01 |
| UV | 365 | 10 | 244 mW | 30 | UVS365 |
| UV | 375 | 150 mW | 30 | UVS375 | |
| UV | 385 | 160 mW | LW385 | ||
| UV | 395 | 20 | 250 mW | 10 | UVR01 |
| UV | 405 | 310 mW | LW405 | ||
| 420 | 14 mW | LW420 | |||
| 430 | 14 mW | LW430 | |||
| 435 | 720 mW | LW435 | |||
| 450 | 80 mW | LW450 | |||
| Royal Blue | 455 | 20 | 55 mW | 10 | KBL01 |
| Blue | 470 | 25 | 18 cd | 10 | BLL01 |
| Cyan | 505 | 30 | 80 mW | 10 | CYL01 |
| 525 | 90 mW | LW525 | |||
| Green | 530 | 35 | 14 mW | 10 | GRL01 |
| 565 | 12 mW | LW565 | |||
| 570 | 36 mW | LW570 | |||
| Amber | 590 | 14 | 60 mW | 10 | GEL01 |
| Red Orange | 610 | 20 | 40 mW | 10 | ORL01 |
| 620 | 120 mW | LW620 | |||
| Red | 625 | 20 | 30 mW | 10 | RTL01 |
| 630 | 150 mW | LW630 | |||
| 645 | 120 mW | LW645 | |||
| 660 | 210 mW | LW660 | |||
| 670 | 450 mW | LW670 | |||
| 680 | 300 mW | LW680 | |||
| 690 | 500 mW | LW690 | |||
| 700 | 500 mW | LW700 | |||
| 735 | 1000 mW | LW735 | |||
| 740 | 900 mW *) | LW740 | |||
| 750 | 800 mW *) | LW750 | |||
| 760 | 1000 mW *) | LW760 | |||
| 780 | 1100 mW *) | LW780 | |||
| 790 | 1000 mW *) | LW790 | |||
| 810 | 1000 mW *) | LW810 | |||
| 830 | 1000 mW *) | LW830 | |||
| 850 | 1500 mW *) | LW850 | |||
| 870 | 1600 mW *) | LW870 | |||
| IR | 880 | 30 | 600 mW *) | 20 | IRR01 |
| 890 | 850 mW *) | LW890 | |||
| 910 | 1200 mW *) | LW910 | |||
| 940 | 700 mW *) | LW940 | |||
| 950 | 700 mW *) | LW950 | |||
| 970 | 240 mW *) | LW970 | |||
| 990 | 100 mW *) | LW990 | |||
| 1050 | 120 mW *) | LW1050 | |||
| 1200 | 210 mW *) | LW1200 | |||
| 1300 | 110 mW *) | LW1300 | |||
| 1450 | 120 mW *) | LW1450 | |||
| 1550 | 100 mW *) | LW1550 | |||
| Royal Blue to UV (switchable) | 370 428 470 |
10 20 20 |
10 mW 5 mW 15 mW |
30 30 30 |
BUVZ01 |
*) Max. output power only available with PP211 (CIMPS-2 and CIMPS-4)
Tuneable Light Sources for CIMPS
| TLS | |
| Physical dimensions (W x D x H) | 190 x 150 x 134 mm |
| Light source | High power LED |
| Monochromator | USB controller unit |
| Wavelength | 420 - 730 nm |
CIMPS Resources
Product Information
Download the latest information brochure about ZAHNER CIMPS system...
b_cimps.pdf (PDF)
Manual Add-on
Download the latest manual add-on about ZAHNER CIMPS system...
m_cimps.pdf (PDF)
Download the latest manual add-on about ZAHNER CIMPS-abs option for the examination of electro-chromic processes...
m_cimps_abs.pdf (PDF)
Download the latest manual add-on about ZAHNER CIMPS-pcs option for the examination of solar cells, DSSC, OSC,...
m_cimps_pcs.pdf (PDF)
Product Information
Download the latest information brochure about ZAHNER CIMPS system...
b_cimps.pdf (PDF)Manual Add-on
Download the latest manual add-on about ZAHNER CIMPS system...
m_cimps.pdf (PDF)Download the latest manual add-on about ZAHNER CIMPS-abs option for the examination of electro-chromic processes...
m_cimps_abs.pdf (PDF)Download the latest manual add-on about ZAHNER CIMPS-pcs option for the examination of solar cells, DSSC, OSC,...
m_cimps_pcs.pdf (PDF)