ZAHNER® Solutions
Thales Software Package

The powerful Thales software package is part of the standard equipment of each IM6 and ZENNIUM system. It provides a multitude of measuring and analysis methods.

Thales main menu
The Thales software provides unique features for the acquisition and analysis. The most prominent examples are SCRIPT and SIM. SCRIPT offers you to combine all types of electrochemical measurements, mathematical analysis, algorithms, documentation and data export to a reproducible, fully automatic process. With the outstanding features of SIM you are able to create equivalent circuits and fit the measurement data to these models. The ZHIT feature of SIM helps you to validate your impedance spectra.
For evaluation only it is also possible to run Thales Software Package on a Thales Box. The Thales Box provides a single user licence of Thales. So you can process your recorded data on a simple PC or Laptop meanwhile your tests still runs on the IM6 or ZENNIUM...

System requirements:
• IBM compatible PC with Microsoft® Windows® 32-/64-Bit operating system
• Signated driver for Windows® XP, Windows Vista® and Windows® 7
• USB 1.1/2.0

Look & Feel
Free scaleable application window Windows tooltips
Free scaleable application window Windows® tooltips
Fast online help system Thalesviewer (Windows Explorer Extensions)
Fast online help system Thalesviewer
(Windows Explorer® Extensions)
Direct access pull down menu Child windows for configurable online measurement display
Direct access pull down menu Child windows for configurable online measurement display
back


Basic Functions & Methods
Electrochemical Impedance Spectroscopy (EIS)

EIS measures the impedance of your test element at different frequencies. This impedance spectrum characterizes the individual partial elements of your test system.
Applications: Determine different parameters like diffuision capacity, ohmic resistance, and so on.

EIS: Recording Z spectrum with realtime instruments EIS: Investigate impedance spectrum with cursors
Measuring impedance spectrum with realtime instruments Investigate impedance spectrum with cursors
Download EIS Manual...
PDF-Document EIS.pdf (PDF)

back



(Multi Cell)I/E Scans & Cyclic Voltammetry (IE, CV)

I/E and CV measures voltage current curves in many different modes.
Applications: Tafel Scans, CVs, steady-state-, sampling - & dynamic current/voltage scans, fast cyclic voltammetry, potentiostatic/galvanostatic polarization, voltage/current vs. time, linear scans, multiple cell parallel dynamic I/E characteristics.

Download I/E Manual...
PDF-Document IE.pdf (PDF)

Download MultiCell I/E Manual...
PDF-Document MCIE.pdf (PDF)

Download CV Manual...
PDF-Document CV.pdf (PDF)

Download POL Manual...
PDF-Document POL.pdf (PDF)

back



Single Frequency Impedance Measurement over Parameters (CE)

CE measures the impedance at a fixed frequency vs. other variable physical dimensions.
Applications: Fixed frequency impedance course vs. potential, current, time, temperature...

Download C/E Manual...
PDF-Document CE.pdf (PDF)

back



Universal Userdefined Measurements (PVI)

PVI allows voltage/current/time measurements in a userdefined way (steps, ramps, plateaus, loops,...).
Applications: ...

Download PVI Manual...
PDF-Document PVI.pdf (PDF)

back



Signal Acquisition (ACQ)

ACQ is an interface for a lot of additional measurement channels.
Application: Setup and integrate TEMP/U, DIO, DA4, Eurotherm, virtual instruments and so on...

Download ACQ Manual...
PDF-Document ACQ.pdf (PDF)

Supported Hardware back



Polarography Measurements (PGY)

Polarography offers the following methods: tast polarography, differential pulse polarography and differential pulse voltammetry (stripping voltammetry)
Applications: ...

Download Polarography Manual...
PDF-Document PGY.pdf (PDF)

back



Equivalent Circuit Simulation & Model Fit (SIM)

Process time dependent spectra and analyze the parameter course of model series.
Applications: Investigate spectra measured by EIS, smooth diagrams, select samples, edit equivalent circuit models, fit single/series measurements, analyse transfer function series and analyse measure series.

SIM: Main menu SIM: Edit model of equivalent circuit
SIM main menu Edit model of equivalent circuit
SIM: Select samples for fitting SIM: Fit model to measurement
Select samples for fitting Fit model to measurement
Download an overview about ZAHNER SIM software...
PDF-Document sim_overview.pdf (PDF)

Download SIM Manual...
PDF-Document SIM.pdf (PDF)

back



Import External ASCII Data (ALEX)

Import external ASCII data listings into thales environment for analysis.
Applications: This function offers you a unique interface for different kinds of data formats.

Download ALEX Manual...
PDF-Document ALEX.pdf (PDF)

back



Automatize Measurements Script Server (SCRIPT)

Automatize combined measurement, analysis- and documentation tasks. Integrate situation dependent processing, branches, loops and so on.
Applications: SCRIPT enables each user to create his own procedure in an easy-to-learn BASIC-like language which uses a lot of powerful macro-commands. If needed, a complete set of andiBASIC commands is available. This makes measurements comfortable and easy to handle - even for untrained staff.

SCRIPT: Linked example and SCRIPT Editor SCRIPT: Editor with online help
Linked example and SCRIPT Editor SCRIPT Editor with online help
Download an overview about ZAHNER SCRIPT software...
PDF-Document script_overview.pdf (PDF)

Download SCRIPT Manual...
PDF-Document SCRIPT.pdf (PDF)

back



Call/Integrate SCRIPT Runtime Modules (EXE)

With EXE you can start SCRIPT runtime modules in an easy way.
Application: Integration of ready linked scripts in the thales main screen and special applications like CIMPS, COLT, RV, REMOTE, ...

back



Assemble, Edit & Export Graphics (CAD)

CAD is the thales graphic editor for ICD-formated graphic files.
Application: Edit graphics/diagrams/reports, customize screenshots, export graphics to enhanced meta files (EMF) or clipboard.

Download CAD Manual...
PDF-Document CAD.pdf (PDF)

back



DC Cycling Script for Battery Applications with AC-EIS Spectroscopy During Ramps (BAT)

Battery Cycling is a script application for automated DC cycling with AC-EIS spectroscopy during ramps.
Application: Battery applications

Battery Cycling: Main menu DC cycling measurement of an AAA microcell
Battery Cycling main menu DC cycling measurement of an AAA microcell
Download BATTERY CYCLING Manual...
PDF-Document BAT.pdf (PDF)

back



TCP/IP VI Remote Control Script

Normally, the IM6/ZENNIUM systems are controlled by the Thales software package which is optimized for measuring and analyzing electrochemical data. In addition, the IM-systems are prepared to be controlled by external software using the TCP/IP protocol. This is not limited to the local IM-PC but is also possible over network.
Application: Controlling the basic functions of a IM6 or ZENNIUM by a LabVIEW® VI over TCP/IP

Remote: Control script running TCP/IP connection Remote: ZAHNER ZRemote VI
Remote control script running TCP/IP connection ZAHNER ZRemote VI
Download Remote Control Manual...
PDF-Document REMOTE.pdf (PDF)
back

Microsoft, Windows and Windows Vista are registered trademarks of Microsoft Corporation in the United States and/or other countries.