High-end Data Acquisition Systems
ZAHNER-Elektrik GmbH & Co.KG
Thueringer Strasse 12
96317 Kronach
Germany
support@zahner.de
Stay on Top!
With the Best Solutions
in Electrochemical Applications
With the Best Solutions
in Electrochemical Applications
ZAHNER® Solutions
Thales Software Package
The powerful Thales software package is part of the standard equipment of each IM6 and ZENNIUM system. It provides a multitude of measuring and analysis methods.
The Thales software provides unique features for the acquisition and analysis. The most prominent examples are SCRIPT and SIM. SCRIPT offers you to combine all types of electrochemical measurements, mathematical analysis, algorithms, documentation and data export to a reproducible, fully automatic process. With the outstanding features of SIM you are able to create equivalent circuits and fit the measurement data to these models. The ZHIT feature of SIM helps you to validate your impedance spectra.
For evaluation only it is also possible to run Thales Software Package on a Thales Box. The Thales Box provides a single user licence of Thales. So you can process your recorded data on a simple PC or Laptop meanwhile your tests still runs on the IM6 or ZENNIUM...
System requirements:
• IBM compatible PC with Microsoft® Windows® 32-/64-Bit operating system
• Signated driver for Windows® XP, Windows Vista® and Windows® 7
• USB 1.1/2.0
System requirements:
• IBM compatible PC with Microsoft® Windows® 32-/64-Bit operating system
• Signated driver for Windows® XP, Windows Vista® and Windows® 7
• USB 1.1/2.0
back
Basic Functions & Methods
Electrochemical Impedance Spectroscopy (EIS)
EIS measures the impedance of your test element at different frequencies. This impedance spectrum characterizes the individual partial elements of your test system.
Applications: Determine different parameters like diffuision capacity, ohmic resistance, and so on.
Download EIS Manual...
EIS.pdf (PDF)
back
(Multi Cell)I/E Scans & Cyclic Voltammetry (IE, CV)
I/E and CV measures voltage current curves in many different modes.
Applications: Tafel Scans, CVs, steady-state-, sampling - & dynamic current/voltage scans, fast cyclic voltammetry, potentiostatic/galvanostatic polarization, voltage/current vs. time, linear scans, multiple cell parallel dynamic I/E characteristics.
Download I/E Manual...
IE.pdf (PDF)
Download MultiCell I/E Manual...
MCIE.pdf (PDF)
Download CV Manual...
CV.pdf (PDF)
Download POL Manual...
POL.pdf (PDF)
back
Single Frequency Impedance Measurement over Parameters (CE)
CE measures the impedance at a fixed frequency vs. other variable physical dimensions.
Applications: Fixed frequency impedance course vs. potential, current, time, temperature...
Download C/E Manual...
CE.pdf (PDF)
back
Universal Userdefined Measurements (PVI)
PVI allows voltage/current/time measurements in a userdefined way (steps, ramps, plateaus, loops,...).
Applications: ...
Download PVI Manual...
PVI.pdf (PDF)
back
Signal Acquisition (ACQ)
ACQ is an interface for a lot of additional measurement channels.
Application: Setup and integrate TEMP/U, DIO, DA4, Eurotherm, virtual instruments and so on...
Download ACQ Manual...
ACQ.pdf (PDF)
Supported Hardware back
Polarography Measurements (PGY)
Polarography offers the following methods: tast polarography, differential pulse polarography and differential pulse voltammetry (stripping voltammetry)
Applications: ...
Download Polarography Manual...
PGY.pdf (PDF)
back
Equivalent Circuit Simulation & Model Fit (SIM)
Process time dependent spectra and analyze the parameter course of model series.
Applications: Investigate spectra measured by EIS, smooth diagrams, select samples, edit equivalent circuit models, fit single/series measurements, analyse transfer function series and analyse measure series.
Download an overview about ZAHNER SIM software...
sim_overview.pdf (PDF)
Download SIM Manual...
SIM.pdf (PDF)
back
Import External ASCII Data (ALEX)
Import external ASCII data listings into thales environment for analysis.
Applications: This function offers you a unique interface for different kinds of data formats.
Download ALEX Manual...
ALEX.pdf (PDF)
back
Automatize Measurements Script Server (SCRIPT)
Automatize combined measurement, analysis- and documentation tasks. Integrate situation dependent processing, branches, loops and so on.
Applications: SCRIPT enables each user to create his own procedure in an easy-to-learn BASIC-like language which uses a lot of powerful macro-commands. If needed, a complete set of andiBASIC commands is available. This makes measurements comfortable and easy to handle - even for untrained staff.
Download an overview about ZAHNER SCRIPT software...
script_overview.pdf (PDF)
Download SCRIPT Manual...
SCRIPT.pdf (PDF)
back
Call/Integrate SCRIPT Runtime Modules (EXE)
With EXE you can start SCRIPT runtime modules in an easy way.
Application: Integration of ready linked scripts in the thales main screen and special applications like CIMPS, COLT, RV, REMOTE, ...
back
Assemble, Edit & Export Graphics (CAD)
CAD is the thales graphic editor for ICD-formated graphic files.
Application: Edit graphics/diagrams/reports, customize screenshots, export graphics to enhanced meta files (EMF) or clipboard.
Download CAD Manual...
CAD.pdf (PDF)
back
DC Cycling Script for Battery Applications with AC-EIS Spectroscopy During Ramps (BAT)
Battery Cycling is a script application for automated DC cycling with AC-EIS spectroscopy during ramps.
Application: Battery applications
Download BATTERY CYCLING Manual...
BAT.pdf (PDF)
back
TCP/IP VI Remote Control Script
Normally, the IM6/ZENNIUM systems are controlled by the Thales software package which is optimized for measuring and analyzing electrochemical data. In addition, the IM-systems are prepared to be controlled by external software using the TCP/IP protocol. This is not limited to the local IM-PC but is also possible over network.
Application: Controlling the basic functions of a IM6 or ZENNIUM by a LabVIEW® VI over TCP/IP
Download Remote Control Manual...
REMOTE.pdf (PDF)
back
EIS measures the impedance of your test element at different frequencies. This impedance spectrum characterizes the individual partial elements of your test system.
Applications: Determine different parameters like diffuision capacity, ohmic resistance, and so on.
![]() |
![]() |
| Measuring impedance spectrum with realtime instruments | Investigate impedance spectrum with cursors |
EIS.pdf (PDF)back
(Multi Cell)I/E Scans & Cyclic Voltammetry (IE, CV)
I/E and CV measures voltage current curves in many different modes.
Applications: Tafel Scans, CVs, steady-state-, sampling - & dynamic current/voltage scans, fast cyclic voltammetry, potentiostatic/galvanostatic polarization, voltage/current vs. time, linear scans, multiple cell parallel dynamic I/E characteristics.
Download I/E Manual...
IE.pdf (PDF)Download MultiCell I/E Manual...
MCIE.pdf (PDF)Download CV Manual...
CV.pdf (PDF)Download POL Manual...
POL.pdf (PDF)back
Single Frequency Impedance Measurement over Parameters (CE)
CE measures the impedance at a fixed frequency vs. other variable physical dimensions.
Applications: Fixed frequency impedance course vs. potential, current, time, temperature...
Download C/E Manual...
CE.pdf (PDF)back
Universal Userdefined Measurements (PVI)
PVI allows voltage/current/time measurements in a userdefined way (steps, ramps, plateaus, loops,...).
Applications: ...
Download PVI Manual...
PVI.pdf (PDF)back
Signal Acquisition (ACQ)
ACQ is an interface for a lot of additional measurement channels.
Application: Setup and integrate TEMP/U, DIO, DA4, Eurotherm, virtual instruments and so on...
Download ACQ Manual...
ACQ.pdf (PDF)Supported Hardware back
Polarography Measurements (PGY)
Polarography offers the following methods: tast polarography, differential pulse polarography and differential pulse voltammetry (stripping voltammetry)
Applications: ...
Download Polarography Manual...
PGY.pdf (PDF)back
Equivalent Circuit Simulation & Model Fit (SIM)
Process time dependent spectra and analyze the parameter course of model series.
Applications: Investigate spectra measured by EIS, smooth diagrams, select samples, edit equivalent circuit models, fit single/series measurements, analyse transfer function series and analyse measure series.
![]() |
![]() |
| SIM main menu | Edit model of equivalent circuit |
![]() |
![]() |
| Select samples for fitting | Fit model to measurement |
sim_overview.pdf (PDF)Download SIM Manual...
SIM.pdf (PDF)back
Import External ASCII Data (ALEX)
Import external ASCII data listings into thales environment for analysis.
Applications: This function offers you a unique interface for different kinds of data formats.
Download ALEX Manual...
ALEX.pdf (PDF)back
Automatize Measurements Script Server (SCRIPT)
Automatize combined measurement, analysis- and documentation tasks. Integrate situation dependent processing, branches, loops and so on.
Applications: SCRIPT enables each user to create his own procedure in an easy-to-learn BASIC-like language which uses a lot of powerful macro-commands. If needed, a complete set of andiBASIC commands is available. This makes measurements comfortable and easy to handle - even for untrained staff.
![]() |
![]() |
| Linked example and SCRIPT Editor | SCRIPT Editor with online help |
script_overview.pdf (PDF)Download SCRIPT Manual...
SCRIPT.pdf (PDF)back
Call/Integrate SCRIPT Runtime Modules (EXE)
With EXE you can start SCRIPT runtime modules in an easy way.
Application: Integration of ready linked scripts in the thales main screen and special applications like CIMPS, COLT, RV, REMOTE, ...
back
Assemble, Edit & Export Graphics (CAD)
CAD is the thales graphic editor for ICD-formated graphic files.
Application: Edit graphics/diagrams/reports, customize screenshots, export graphics to enhanced meta files (EMF) or clipboard.
Download CAD Manual...
CAD.pdf (PDF)back
DC Cycling Script for Battery Applications with AC-EIS Spectroscopy During Ramps (BAT)
Battery Cycling is a script application for automated DC cycling with AC-EIS spectroscopy during ramps.
Application: Battery applications
![]() |
![]() |
| Battery Cycling main menu | DC cycling measurement of an AAA microcell |
BAT.pdf (PDF)back
TCP/IP VI Remote Control Script
Normally, the IM6/ZENNIUM systems are controlled by the Thales software package which is optimized for measuring and analyzing electrochemical data. In addition, the IM-systems are prepared to be controlled by external software using the TCP/IP protocol. This is not limited to the local IM-PC but is also possible over network.
Application: Controlling the basic functions of a IM6 or ZENNIUM by a LabVIEW® VI over TCP/IP
![]() |
![]() |
| Remote control script running TCP/IP connection | ZAHNER ZRemote VI |
REMOTE.pdf (PDF)back
Microsoft, Windows and Windows Vista are registered trademarks of Microsoft Corporation in the United States and/or other countries.
Thales Z 2.0 Software
Look & Feel
Basic Functions & Methods
Software Options
Look & Feel
![]() |
Scaleable Window Windows® Tooltips Fast Online Help Explorer Extensions Direct Access Menu Online Displays |
Software Options
![]() |
Electrochemical Noise (Noise) |
![]() |
High Current Interrupt (HCI) with Pulse Software |
![]() |
Controlled Intensity Modulated Photo Spectroscopy (CIMPS) |
![]() |
Coating & Laminate Tester (COLT) |
![]() |
Relaxation Voltammetry (RV) |